**************************************************************************** Cronyx E1-XL-FX-SNMP Mode: Normal, Clock=Link0, SaBits=Ones, Sig=Kewl start, Ring cadence=1:4, Echo=On, Sensor=Open Link 0: High gain, HDB3, TS16=CAS, CRC4=Gen, Mon=Sa4, Ok Link 1: Disabled FXS 0: 0-Idle 0/0, 1-Idle 0/0, 2-Idle 0/0, 3-Idle 0/0 FXO 1: 4-Idle 0/0, 5-Idle 0/0, 6-Idle 0/0, 7-Idle 0/0 Timeslots: 1 3 5 7 9 1 3 5 7 9 1 3 5 7 9 1 Link 0: 01234567.......*............... Main menu: 1) Statistics 2) Event counters 3) Loops... 4) Link test... 5) Configure... 0) Reset Command: **************************************************************************** Common: 1) Master clock: Link0 2) Sa bits: All ones 3) Sensor input: Alarm on closed 4) Type of signaling: Kewl start 5) Ring cadence: 1:4 6) Echo canceller: On **************************************************************************** Timeslots: Use arrow keys to select the timeslot. Set timeslot usage by entering symbol as follows: 0-9, A-F - FXO/FXS line number; = - transparent pass between links; . - idle. Timeslots: 1 3 5 7 9 1 3 5 7 9 1 3 5 7 9 1 Link 0: 01234567.......*............... Link 1: ...............*............... **************************************************************************** Link 0: 1) CAS: Yes 2) Crc4: Generate 3) Receiver gain: High 4) Monitoring channel bit: Sa4 5) Loss of sync action: Remote Alarm 6) Line code: HDB3 7) Auto AIS: Never 8) Remote control: Enabled 9) Enabled: Yes **************************************************************************** FXS 0: 1) Line 0 gain: TX 0, RX 0 dB 2) Line 1 gain: TX 0, RX 0 dB 3) Line 2 gain: TX 0, RX 0 dB 4) Line 3 gain: TX 0, RX 0 dB 5) Line 0 power: On 6) Line 1 power: On 7) Line 2 power: On 8) Line 3 power: On **************************************************************************** FXO 1: 1) Line 4 gain: TX 0, RX 0 dB 2) Line 5 gain: TX 0, RX 0 dB 3) Line 6 gain: TX 0, RX 0 dB 4) Line 7 gain: TX 0, RX 0 dB